Category | Selection table | |||||
Model number | RH-H22-0325 | RH-H38-0537 | RH-H38-0855 | RH-H38-1075 | RH-H38-1511 | RH-H38-2015 |
Power system | Single-phase 220V | Three-phase 380V(50HZ) | ||||
Electric heating capacity | 3KW | 5KW | 8KW | 10KW | 15KW | 20KW |
Applicable area | ≤12m² | ≤18m² | ≤30m² | ≤40m² | ≤50m² | ≤70m² |
Constant temperature | <60ºC | |||||
0utlet temperature | Reference graph | |||||
Temperature control form | PID control /SSR drive(SCR optional) | |||||
0utlet diameter | φ89mm | φ133mm | φ220mm | |||
Fan power | 0.25KW | 0.37KW | 0.55KW | 0.75KW | 1.1KW | 1.5KW |
Rated air volume | 9m³/min | 11m³/min | 15m³/min | 22m³/min | 26m³/min | 28m³/min |
Rated vind pressure | 860pa | 1000pa | 1100pa | 1500pa | 1200pa | 1350pa |
Inlet diameter | φ100mm | φ100mm | φ133mm | |||
Modulated pattern | Mechanical damper (variable frequency) | |||||
Allowable intake air temperature |
<180ºC(customizable higher) | |||||
vocality | <70db | |||||
Cable configuration specifications |
3×4mm2+1-3M | 3×4mm2+2-3M | 3×6mm2+2-3M | 3×10mm2+2-3M | ||
Installation mode | Fixed on wheels or bolts | |||||
Weight (approx) | 30KG | 50KG | 55KG | 60KG | 90KG | 95KG |
Use environment | ≥-30≤42ºC The air humidity is less than<80% | |||||
Special function | Humidity controller can be installed in the drying room to realize dual linkage and automatic risk control system | |||||
Condition statement | The applicable area data is measured on the basis of good thermal insulation and reasonable exhaust on six sides of the thermal insulation room | |||||
Dimensions (length width height mm) |
735×275x452 | 800×325×600 | 950×345×750 | 960×345×750 | 1000×485×838 | 1020×485×838 |
Category | Selection table | |||||
Model number | RH-H38-3022 | RH-H38-4022 | RH-H38-5022 | RH-H38-6022 | RH-H38-8040 | RH-H38-10040 |
Power system | Three-phase 380V(50HZ) | |||||
Electric heating capacity | 30KW | 40KW | 50KW | 60KW | 80KW | 100KW |
Applicable area | ≤100m² | ≤130m² | ≤160m² | ≤200m² | ≤280m² | ≤350m² |
Constant temperature | <60ºC | |||||
0utlet temperature | Reference graph | |||||
Temperature control form | PID control /SSR drive(SCR optional) | |||||
0utlet diameter | φ220mm | φ300mm | ||||
Fan power | 2.2KW | 2.2KW | 4KW | |||
Rated air volume | 34m³/min | 140m³/min | 206m³/min | |||
Rated vind pressure | 1600pa | 1350pa | 1650pa | |||
Inlet diameter | φ220mm | φ300mm | ||||
Modulated pattern | Mechanical damper (variable frequency) | |||||
Allowable intake air temperature |
<180ºC(customizable higher) | |||||
vocality | <70db | |||||
Cable configuration specifications |
3×10mm²+2-3M | 3X16mm²+2-3M | 3X25mm²+2-3M | 3X25mm²+1-your own | 3X35mm²+1-your own | 3X50mm²+1-your own |
Installation mode | Fixed on wheels or bolts | |||||
Weight (approx) | 100KG | 102KG | 110KG | 240KG | 290KG | 350KG |
Use environment | ≥-30≤42ºC The air humidity is less than<80% | |||||
Special function | Humidity controller can be installed in the drying room to realize dual linkage and automatic risk control system | |||||
Condition statement | The applicable area data is measured on the basis of good thermal insulation and reasonable exhaust on six sides of the thermal insulation room | |||||
Dimensions (length width height mm) |
1050×485×838 | 1070×485×838 | 1780×485×838 | 1780×750×1092 | 1880×750x1092 | 2185×750×1092 |